Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 390G — Lap Joints, Fire Cracks
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 390H, 390I. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 390 g
Reg. 390 h
Reg. 390 i
|
Earlier text: the 2008 DIPP web edition
Lap Joints, Fire Cracks
Lap-joint boilers are apt to crack where the plates lap in the longitudinal or straight seam; if there is any evidence of leakage or other distress at this point, it shall be thoroughly investigated and, if necessary, rivets removed or the plate slotted in order to determine whether cracks exist in the seam. Any cracks noted in shell plates are usually dangerous except fire cracks that run from the edge of the plate into the rivet holes of girth seams. A limit number of such fire cracks is not usually a very serious matter.