Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 38 — Tensile strength
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine). This page was revised after the 2019 capture, so later amendments may be included. Units as printed.
| [image] | [image] |
| ||||||||||||||||||||||||||||||||||||||||
Earlier text: the 2008 DIPP web edition
MATERIALS OF CONSTRUCTION
COLD DRAWN SEAMLESS STEEL BOILER AND SUPERHEATER TUBES FOR DESIGN METAL TEMPERATURES NOT EXCEEDING 454°C (850°F).
Tensile strength
(a)The tensile strength of the material cut from finished tubes shall conform to one of the following five grades namely:-
(i)31 to 41 kgf/mm2
(ii)36 to 46 kgf/mm2
(iii)41 to 51 kgf/mm2
(iv)46 to 56 kgf/mm2
(v)50 to 62 kgf/mm2
(b)The upper yield point at room temperature shall be not less than 50 per cent of the specified minimum tensile strength at room temperature.
(c)The minimum values of the stress at proof limit 0.2 per cent at elevated temperature Et of the material may be calculated by multiplying the specified minimum tensile strength at room temperature R20 by the ratio Et/R20
Minimum values for the ratio of the stress at proof limit 0.2 per cent at elevated temperature Et to the minimum specified tensile strength at room temperature R20 of carbon steel tubes.
Temperature *250°C *275°C 300°C 325°C 350°C 375°C 400°C 425°C
Et/R20 0.40 0.38 0.36 0.34 0.33 0.32 0.31 0.30
* For temperature lower than 300°C any test required for acceptance purpose (in the absence of record of previous tests at the temperature) shall be made at 300°C, in which case the proof stress shall be not less than the value obtained by calculation from the specified minimum tensile strength at room temperature and the above ratio of 0.36 for 300°C.
(d)The breaking elongation in % shall be not less than (100-Rm) /C
where C = 2.2 for only gauge length of L=5 do or 5.65 (Ao)¹ᐟ²
do = original diameter of the round test piece.
Ao = original cross section of the rectangular test piece.
NOTE: C=1.9 for gauge lengths of 4 Ao or test piece in Appendix -A.
Amendments found
Machine-assisted list from the amending notifications (DPIIT copies; 1990–1998 from scanned Gazette issues on India Code); may be incomplete.
| Date | Notification | Part | Action | What changed (summary) | Web edition |
|---|---|---|---|---|---|
| 2001-04-10 | G.S.R. 219 | Substituted | Replaced as part of the block substitution of regulations 36 to 56 (tube specifications). | listed before the capture | |
| 2004-08-02 | G.S.R. 265 | Amended | Replaces the last-column heading of the chart with hardness (max) HRB/HB. | listed before the capture |