BETAIndependent engineering reference. Source-text verification is ongoing.Verification ongoing.Verification status →
IBRsourceIndian Boiler Regulations, made clear

Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)

Regulation 37 — Selection of Tubes for Test

Unofficial DPIIT web edition · not verified1 amendment found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine). This page was revised after the 2019 capture, so later amendments may be included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
  [image] [image]


Message from
Chairman of Central Boilers Board
•
About Central Boilers
Board
•
History of Indian Boiler Regulations
•
Foreword
•
Contents Chapter
Wise
•
Contents Regulation
Wise
•
List of Amendments
•
Indian Boilers
Act 1923
•
Ibr Forms
•
Home
•
Search
•
Help
•
Contact Us

[image]

[image]
Reg. 37
MATERIALS OF CONSTRUCTION

COLD DRAWN SEAMLESS CAR BON STEEL BOILER, SUPERHEATER AND HEAT EXCHANGER TUBES FOR DESIGN METAL TEMPERATURES NOT EXCEEDING 454°C (850°F).

Selection of Tubes for Test

(a)  Test Specimens – (i) Test specimens required for the flattening and expanding/ flaring test specified in regulations 38, 39 and 40 shall be taken from the ends of finished tubes prior to upsetting swaging, expanding or any other forming operations or being cut to length.  They shall be smooth on the ends and free from burrs and flaws.

(ii) If desirable and practicable, tensile test may be carried out on full section of the tubes up to the capacity of the testing machine.  For large size tubes, the tensile test specimen shall consist of strip cut longitudinally from the tube and which is not straightened within the gauge length and further heat treated.

(iii) If any test specimen shows flaws or defective machining it may be discarded and another specimen substituted.

(iv)  All specimens shall be tested at room temperature.

(b)   Number of tests. - The test specified in regulations 38, 39 and 40 shall be made on minimum 2 tubes for first 100 tubes and 1 per 100 or part thereof for tubes over 100 numbers.

[image] [image]
[image] [image] [image]
Message from Chairman of Central Boilers Board • About Central Boiler Board • History of Indian Boiler Regulations • Foreword • Contents Chapter Wise • Contents Regulation Wise • List of Amendments
• Indian Boilers Act 1923 • Ibr Forms • Home • Search • Help • Contact Us
Earlier text: the 2008 DIPP web edition

MATERIALS OF CONSTRUCTION

COLD DRAWN SEAMLESS STEEL BOILER AND SUPERHEATER TUBES FOR DESIGN METAL TEMPERATURES NOT EXCEEDING 454°C (850°F).

Selection of Tubes for Test

Two per cent of the tubes of each thickness and diameter and only one for every 100 or part thereof above 400 tubes of such similar size shall be made available to the Inspecting Officer for testing to the extent of such numbers.

Amendments found

Machine-assisted list from the amending notifications (DPIIT copies; 1990–1998 from scanned Gazette issues on India Code); may be incomplete.

DateNotificationPartActionWhat changed (summary)Web edition
2001-04-10G.S.R. 219SubstitutedReplaced as part of the block substitution of regulations 36 to 56 (tube specifications).listed before the capture