Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 310 — Test
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 311, 312. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 310, Reg. 311, Reg. 312 | |||||||||||||||
Reg. 311 Extension Springs
Reg. 312 Number of Effective Coils
|
Earlier text: the 2008 DIPP web edition
Test
1)The permanent set in the spring (defined as the difference between free height and height measured ten minutes after the spring has been compressed solid three additional times, after pre-setting at room temperature) shall not exceed 0.5% of the free height.
2)Torsion bars shall not show a permanent distortion after being twisted to an angle fifty per cent in excess of the working angle.
Amendments found
Machine-assisted list from the amending notifications (DPIIT copies; 1990–1998 from scanned Gazette issues on India Code); may be incomplete.
| Date | Notification | Part | Action | What changed (summary) | Web edition |
|---|---|---|---|---|---|
| 1994-11-23 | G.S.R. 607 OCR of scan | (1) | Substituted | Replaces sub-regulation (1) limiting permanent set of safety-valve springs to 0.5% of free height. Uncertain: Sub-regulation printed '(I)'. | listed before the capture |