Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 264 — Additional tests before rejection
Text in the DPIIT web edition
Archived copy captured 20 Nov 2019 (Wayback Machine); the same page also prints regulations 265, 265A, 265B. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
|
| ||||||||||||||
Reg. 265 Non-Destructive Tests
Reg. 265 (b) Radiographical Examination
|
Earlier text: the 2008 DIPP web edition
Additional tests before rejection
a)Should any of the test specimens taken in accordance with Regs. 257 to 263 fail to meet the specified requirements one retest shall be allowed for each specimen that fails, provided the following minimum figures have been obtained:
i)Reduction in area 30 per cent.
ii)Any other test except the bend and impact tests, 90 per cent of the specified requirements
b)If a cold bend specimen should fail to meet the specified requirements, two re-tests shall be taken from the same test plate and these shall comply with the requirements of Regulations 261 and 262.
c)If an Izod impact test fails to meet the specified requirements, two re-tests shall be taken from the test plate, one each side of the original specimen and separated from it by not more than 5mm. Both re-tests shall show a minimum Izod impact test value of 20 ft. lb.
d)If it be found there is insufficient metal to permit the preparation of specimens for retest from the remainder of the test plate from which the original specimen was taken the specimen for re-test may be cut from the test plate relating to the opposite end of the same longitudinal seam.