Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 260B — All-weld Metal
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 259, 260, 260A. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
|
| ||||||
Reg. 260
(b) All-weld Metal
|
Earlier text: the 2008 DIPP web edition
All-weld Metal
The ultimate tensile stress shall be not less than the lower limit specified for the plate (see table under Regulation 234).
The elongation shall be not less than 20 per cent on a gauge length of four times the square root of the cross sectional area of the specimen, and the reduction in area not less than 35 per cent.