GIRDER STAYS

GENERAL

Girder Stays for Firebox and Combustion Chamber Crowns

a)Each girder when of the normal type, fitted with stay bolts and nuts, shall be of the double plate inter-connected type of sufficient strength to support its proportion of the load on the crown plate independently of the crown plate.

b)The clear waterway between the crown plate and the underside of the girder bars shall be as large as practicable but in no case less than 1½ inches as in Fig.7.

c)The ends of the girders shall not rest on the landing of the flat crown plate but shall be carefully fitted to bed directly on the bends of the corners of the vertical end or side plates.

d)The toes of the girders shall be solid with the girder plates and not separate pieces attached thereto.

e)Girders shall be properly attached to the crown plate by bolts or screws.

NOTE.- Alternative methods of staying may be used or unstayed firebox, crowns of special or patented design of equivalent strength may be fitted (see Regulations 230, 231 and 232).

f)Where an all welded firebox is fitted, the girder stays may be welded to the firebox prior to stress relieving. The girder stays shall be recessed for waterways as in paragraph

(b)(Figs. 6 and 7).

Such girders shall be securely welded by an approved method to the firebox crown. The method of welding and the proportions of attachment shall be to the satisfaction of the Inspecting Authority.