Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 230 — Marshall Type
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 231, 232. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 230, Reg. 231, Reg. 232 PATENT FIREBOX ROOFS OF LOCOTYPE BOILERS Marshall Type For Messrs. Marshall Sons and Company's patent stayless roof for fireboxes of locotype boilers made of steel in which the centre lines of the corrugations meet the centre lines of the end riveted seams at points not farther distance from the side plates than one-half the inner radius of curvature of the corner formed by the roof and side plate, in order to ensure that the thickness and height of the pressed diagonal corrugations of the chamber are satisfactory, the working pressure shall not exceed the smaller of the values obtained from the following formulae:-
where t is the thickness of the roof plate in 32nds of an inch, H is the height of the corrugation at its highest part measured perpendicularly on one side of the plate in inches, W is the width of the roof plate between the flat of side plate at top less the inner radius of curvature of corner of roof and side plate in inches, i.e. W + radius = internal width of firebox at top, L is the length of the roof plate between centre lines rivets in inches. Reg. 231 PATENT FIREBOX ROOFS OF LOCOTYPE BOILERS Garrett Type For Messrs. Richard Garrett and Son's corrugated stayless roof for fireboxes of locotype boilers made of steel in which the side corrugations are parts of true circles and the radius of the middle corrugation is not more than about 1/4th of the radius of the outer corrugations and the corrugations are cambered longitudinally, the working pressure shall not exceed the smaller of the values obtained from the following formulae :-
Where t is the thickness of the corrugated plate in 32nds of an inch, L is the length of the roof plate between centre lines of rivets in inches, R is the external radius of the side corrugations at the middle of the length in inches, C = 363 where the roof and side plates are in one piece and 325 when they are riveted, C1= 12.5 where the roof and side plates are in one piece and 11.25 where they are riveted. Reg. 232 PATENT FIREBOX ROOFS OF LOCO TYPE BOILERS Fowler Type
|
Earlier text: the 2008 DIPP web edition
PATENT FIREBOX ROOFS OF LOCOTYPE BOILERS
Marshall Type
For Messrs. Marshall Sons and Company's patent stayless roof for fireboxes of locotype boilers
made of steel in which the centre lines of the corrugations meet the centre lines of the end
riveted seams at points not farther distance from the side plates than one-half the inner radius
of curvature of the corner formed by the roof and side plate, in order to ensure that the
thickness and height of the pressed diagonal corrugations of the chamber are satisfactory, the
working pressure shall not exceed the smaller of the values obtained from the following
formulae:-
25000 ( t - 1 ) x H2
W. P. = Eqn.(66)
W x L x ( W2 + L2)¹ᐟ²
55 ( t - 1 )2 x ( W +( ( W2 x L2 )²)¹ᐟ²
W. P. = Eqn.(67)
W2 x L2
where t is the thickness of the roof plate in 32nds of an inch,
H is the height of the corrugation at its highest part measured perpendicularly on one side of the plate in inches,
W is the width of the roof plate between the flat of side plate at top less the inner radius of curvature of corner of roof and side plate in inches, i.e. W + radius = internal width of firebox at top,
L is the length of the roof plate between centre lines rivets in inches.
Possible IBR 2026 successors (heading match, unverified): Reg. 237