Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 131 — Longitudinal Stays
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 130, 132. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 130, Reg. 131, Reg. 132 STAYS Bar Stays Bar stays shall not be welded at any part. They shall preferably have plus threads, the ends of the stays being upset or the middle portion being reduced for this purpose. Stay bars which have been worked in the fire shall be subsequently annealed. Reg. 131 STAYS Longitudinal Stays
Reg. 132 STAYS Nuts and Washers for Stays
|
Earlier text: the 2008 DIPP web edition
STAYS
GENERAL
Longitudinal Stays
a)Longitudinal and similar solid screwed stays shall be efficiently secured with nuts at each end and not merely revived over. Where they are over 12 feet in length, they shall be supported at intervals of 6 ft. along its length.
b)Where the stay is screwed through both plates, the stay and holes shall have a continuous thread and fitted with nuts and washers on the outside. Where the stay passes through clearing holes an internal nut and washer shall also be fitted. Where the stay is not normal to the surface of the plate the washer shall be shaped so as to form a true surface for the nuts or a knuckle joint may be fitted.
c)In vertical boilers the stays shall either be screwed into both crown plates or screwed into the furnace crown plate and passed through clearing holes in the shell crown plate.