Regulation 130 — Bar Stays
Unofficial DPIIT web edition · not verified0 amendments found
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 131, 132. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
| Reg. 130, Reg. 131, Reg. 132 STAYS Bar Stays Bar stays shall not be welded at any part. They shall preferably have plus threads, the ends of the stays being upset or the middle portion being reduced for this purpose. Stay bars which have been worked in the fire shall be subsequently annealed. Reg. 131 STAYS Longitudinal Stays
Reg. 132 STAYS Nuts and Washers for Stays
|
Earlier text: the 2008 DIPP web edition
STAYS
GENERAL
Bar Stays
Bar stays shall not be welded at any part. They shall preferably have plus threads, the ends of the stays being upset or the middle portion being reduced for this purpose. Stay bars which have been worked in the fire shall be subsequently annealed.