Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 121 — Furnaces in general
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine). The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 121 FURNACES Furnaces in general
|
Earlier text: the 2008 DIPP web edition
FURNACES
GENERAL
Furnaces in general
a)No furnace or firebox top, whether plain or corrugated, shall exceed 7/8 inch in thickness, and all circular sectioned furnaces when new shall be as near the truly circular form as the type of joint will permit.
b)The use of Z angle rings for furnace foundation seems shall be prohibited.
c)As an alternative to riveting furnaces, furnace crowns, uptakes and other plates not in tension may be jointed by fusion welding provided the conditions laid down in Regulation 122 to 129 are complied with. The end connections of such plates to the shell or shell crown shall also comply with such conditions. This construction shall not apply to furnaces of Lancashire and Cornish type boilers consisting wholly of plain sections.