Reg. 60
MATERIALS OF CONSTRUCTION

Tensile Test

 

Tensile Test.- (a) The tensile strength of the material cut from the finished tube shall conform to the following requirement.

_________________________________________________________________________

Tube                       Yield  strength                      Tensile strength          % Elongation+

Grade                      Mpa(kgf/mm sq.)                 Mpa(kgf/mm2)

                                      (Min)                                     (Min)                                          (Min)___________
WC1                            195                                          320/480                                 25                                                                     (19.9)                                      (32.6/49.0)                                                                  WC2                            235                                          360/500                                 24                                                                   (24.0)                                                         (36.7/51.00)                                   WC3                            245                                          440/580                                 21 _____________       (25.0)                                      (44.9/59.2)___________________________

+ On gauge length 5.65ÖA where A is the initial cross sectional area of the specimen on the gauge length.

(b) Allowable permissible stress at elevated temperature. Allowable permissible stress as per the respective code  shall be strictly followed.

 

Earlier text: the 2008 DIPP web edition

MATERIALS OF CONSTRUCTION

ELECTRICAL -RESISTR|ANCE -WELED STEEL BIOLER AND SUPER-HEATER TUBES FOR DESIGN METAL TEMPERATURES NOT EXCEEDING 454⁰ C (850⁰ F)

Tensile Test

(a)The tensile strength of the material cut from the finished tube shall conform to the following requirement.

Tube                          Yield strength  Tensile strength    % Elongation+
Grade                         Mpa(kgf/mm sq.) Mpa(kgf/mm²)        Over 0.8
                              (Min)           (Min)               (Min)

                              195             320/480
WC1                           (19.9)          (32.6/49.0)         25
WC2                           235             360/500             24
                              (24.0)          (36.7/51.00)
WC3                           245             440/580             21
                              (25.0)          (44.9/59.2)

+ On gauge length 5.65(A)¹ᐟ² where A is the initial cross sectional area of the specimen on the gauge length.

(b)Allowable permissible stress at elevated temperature. Allowable permissible stress as per the respective code shall be strictly followed.

Amendments found

Machine-assisted list from the amending notifications (DPIIT copies; 1990–1998 from scanned Gazette issues on India Code); may be incomplete.

DateNotificationPartActionWhat changed (summary)Web edition
1969-03-01/1988-12-31compilation-1969-1988#p25 OCR of compilationSubstitutedReplaces regulation 60 (tensile strength).listed before the capture
1999-10-14G.S.R. 345SubstitutedReplaced as part of the block substitution of regulations 57 to 63A (electrically welded tubes).listed before the capture