Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 5A — Material not fully identified
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine). The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 5 A Material not fully identified: |
| Where the material as for example plate, bar, billet, pipes and tubes are not covered by mill test certificate either due to misplacement or late receipt of the same but otherwise there are reasons to believe that the materials are genuine and of standard specifications registering authority or Chief Inspector of Boilers may permit the use of such materials as a special case after thorough verification test in a Test house to his satisfaction at the rate not less than 25% subject to the following conditions:- (a) In respect of Plates-
(b) For Billets, bars, pipes and tubes- Shipping documents shall be made available to establish the specifications for manufacture for inspection and testing. |
Earlier text: the 2008 DIPP web edition
Material not fully identified:
Where the material as for example plate, bar, billet, pipes and tubes are not covered by mill test certificate either due to misplacement or late receipt of the same but otherwise there are reasons to believe that the materials are genuine and of standard specifications by the Inspecting Authority; the registering authority may permit the use of such materials as a special case after thorough verification test in a Test house to his satisfaction at the rate not less than 25% subject to the following conditions:-
(a)In respect of Plates-
(i)The plates shall have a steel maker’s stamp.
(ii)Use of such uncertified plates, however, will not be allowed for manufacture of Shell or Drum of the boilers.
(iii)Shipping documents/order documents shall be made available to establish the specifications of the manufacture for inspection and testing of plates.
(b)For Billets, bars, pipes and tubes-
Shipping documents shall be made available to establish the specifications for manufacture for inspection and testing.
Amendments found
Machine-assisted list from the amending notifications (DPIIT copies; 1990–1998 from scanned Gazette issues on India Code); may be incomplete.
| Date | Notification | Part | Action | What changed (summary) | Web edition |
|---|---|---|---|---|---|
| 1969-03-01/1988-12-31 | compilation-1969-1988#p9 OCR of compilation | Inserted | Inserts regulation 5A on material not fully identified. | listed before the capture | |
| 2001-08-28 | G.S.R. 496 | Amended | Replaces the words naming the Inspecting Authority and registering authority with 'registering authority or Chief Inspector of Boilers'. | listed before the capture |