Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)

Regulation 54C — Expanding Tests

Unofficial DPIIT web edition · not verified0 amendments found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine). The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
Reg. 54 c
MATERIALS OF CONSTRUCTION

SEAMLESS FERRITIC PIPES FOR HIGH TEMPERATURE SERVICE

Flattening Tests

(i)For pipes of outside diameter over 60.3 mm a flattening test shall be conducted.  A section of the pipe not less than 63 mm is length shall be flattened cold between two parallel flat surfaces to a distance between the plates (H) as calculated by the formula given below, without showing any sign of a crack or flaw. 

H = (1+e) t / {e + (t/D)}      

where t  = specified thickness for pipe (mm)

          D = specified outside diameter of the pipe (mm)

          e = a constant, 0.08 for ferritic alloy steel.

(ii)  For pipe whose diameter equals or exceeds 254 mm, a bend test may be conducted instead of the flattening test.  The bend test specimens shall be bent at room temperature through 180 degree C without cracking on the outside of the bent portion.  The inside diameter of the bend shall be 25 mm.  Substitution of the bend test for the flattening test shall be subject to the approval of the purchaser.

(iii)  For pipes whose diameter exceed 635 mm and whose diameter to wall thickness ratio is 7.0 or less, the bend test described in clause (b) shall be conducted instead of the flattening test.

Earlier text: the 2008 DIPP web edition

MATERIALS OF CONSTRUCTION

SEAMLESS CHROMIUM-MOLYBDENUM STEEL BOILER AND SUPER HEATER TUBES FOR DESIGN METAL TEMPERATURES NOT EXCEEDING 538 DEGREE C (1,000 DEGREE F).

Expanding Tests

The tubes shall withstand expanding by a drift expander having a total included angle of between 40° and 60° (20° and 30° per side) to the following increases in external diameter without showing crack or flaw:-

Thickness of Tube                             Increase in Diameter per cent
10 S.W.G. and thinner                         12½
Thicker than 10 S.W.G. upto and including 6 S.W.G. 9½
Thicker than 6                                6½

In lieu of the expanding test, the flaring test carried out in accordance with any other standard code may be accepted in which case the Code adopted shall be specified.