Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 54B — Flattening Test
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine). The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 54 b MATERIALS OF CONSTRUCTION SEAMLESS FERRITIC PIPES FOR HIGH TEMPERATURE SERVICE Bend Test |
| For pipes of outside diameter 60.3 mm and under, a bend test shall be conducted. A sufficient length of pipe shall stand being bent cold through 90 around a cylindrical mandrel, the diameter of which is 12 times the nominal diameter of the pipe, without developing cracks. |
Earlier text: the 2008 DIPP web edition
MATERIALS OF CONSTRUCTION
SEAMLESS CHROMIUM-MOLYBDENUM STEEL BOILER AND SUPER HEATER TUBES FOR DESIGN METAL TEMPERATURES NOT EXCEEDING 538 DEGREE C (1,000 DEGREE F).
Flattening Test
A ring not less than 2 inches in length cut from one end of each selected tube shall be flattened between two parallel flat surfaces the width of which shall be not less than 1½ times the diameter of the tube. When the pressure is released, the interior surfaces of the test pieces at the middle shall remain at a distance apart of not more than three times the specified thickness of the tube and the test piece shall then show no sign of crack or flaw.
The flattening test carried out in accordance with any other standard code may be accepted in which case the Code adopted shall be specified.