Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 53D — Selection of Tubes for testing
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine). This page was revised after the 2019 capture, so later amendments may be included. Units as printed.
| [image] | [image] |
| ||||||||||||||||
Earlier text: the 2008 DIPP web edition
MATERIALS OF CONSTRUCTION
SEAMLESS CHROMIUM-MOLYBDENUM STEEL BOILER AND SUPER HEATER TUBES FOR DESIGN METAL TEMPERATURES NOT EXCEEDING 538 DEGREE C (1,000 DEGREE F).
Selection of Tubes for testing
After heat-treatment, the tubes shall be presented for mechanical testing in accordance with Regulations 54(a), 54(b) and 54(c) in batches of not more than 100 of the same nominal diameter and thickness. The manufacturer shall provide at his own expense extra tubes at the rate of 2 per cent of each diameter and thickness of tube specified and the Inspecting Officer shall select for test such of the tube as he may think proper to the extent of the percentage mentioned. Should the number of tubes specified of any one nominal size exceed 400, then, for every 100 tubes or part thereof above that number, one additional tube shall be provided. The samples for testing shall not be heat-treated after selection.