Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 536A — Equipment of Workshop
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 535, 536, 537. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 535, Reg. 536, Reg. 536 A, Reg. 537
Reg. 536
Reg. 536 A
Reg. 537
|
Earlier text: the 2008 DIPP web edition
Equipment of Workshop
a)The welding plant and equipment are to be of good quality and maintained in an efficient working condition. The welding apparatus is to be installed under cover and arranged so that welding work may be carried out in positions free from draughts and adverse weather conditions. The procedure is to be such that there is regular and systematic supervision of the welding works, and the welding operators are to be subjected by the works officials to periodic tests for quality of workmanship. Records of these tests are to be kept and are to be available to the Inspecting Officers for scrutiny.
b)The works should be equipped with welding plant equipment and quality control personnel. However, the equipment for destructive, non-destructive testing and heat treatment is not necessary. The manufacturer can tie-up for these facilities outside and a letter from the party with whom he makes a tie-up should be made available to the Chief Inspector of Boilers of the State. Inspecting authority or his representative should be allowed to inspect the material in the laboratory of the party during the test.
Amendments found
Machine-assisted list from the amending notifications (DPIIT copies; 1990–1998 from scanned Gazette issues on India Code); may be incomplete.
| Date | Notification | Part | Action | What changed (summary) | Web edition |
|---|---|---|---|---|---|
| 2010-10-07 | G.S.R. 821(E) | Amended | Replaces the authority wording with 'Inspecting Authority or Chief Inspector, as the case may be'. | listed before the capture | |
| 2010-10-07 | G.S.R. 821(E) | Amended | Replaces 'Inspecting officer(s)' with 'Competent Person' wherever it occurs. | listed before the capture |