Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)

Regulation 49C — Expanding Test

Unofficial DPIIT web edition · not verified0 amendments found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine). This page was revised after the 2019 capture, so later amendments may be included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
  [image] [image]


Message from
Chairman of Central Boilers Board
•
About Central Boilers
Board
•
History of Indian Boiler Regulations
•
Foreword
•
Contents Chapter
Wise
•
Contents Regulation
Wise
•
List of Amendments
•
Indian Boilers
Act 1923
•
Ibr Forms
•
Home
•
Search
•
Help
•
Contact Us

[image]

[image]
Reg. 49 C
MATERIALS OF CONSTRUCTION

SEAMLESS FERRITIC AND AUSTENITIC ALLOY STEEL BOILER, SUPERHEATER AND HEAT EXCHANGER TUBES

Expanding or Flaring Test

A section of the tube approximately 100 mm in length shall stand being flared with a tool having a 60 degree included angle until the tube at the mouth of the flare has been expanded to the percentages given below, without cracking.

Ratio of inside diameter to outside diameter

Minimum expansion of inside diameter %

0.9

21

0.8

22

0.7

25

0.6

30

0.5

39

0.4

51

0.3

68

[image] [image]
[image] [image] [image]
Message from Chairman of Central Boilers Board • About Central Boiler Board • History of Indian Boiler Regulations • Foreword • Contents Chapter Wise • Contents Regulation Wise • List of Amendments
• Indian Boilers Act 1923 • Ibr Forms • Home • Search • Help • Contact Us
Earlier text: the 2008 DIPP web edition

MATERIALS OF CONSTRUCTION

SEAMLESS MOLYBDENUM STEEL BOILER AND SUPERHEATER TUBES FOR DESIGN METAL TEMPERATURE NOT EXCEEDING 510 DEGREE C (950 DEGREE F).

Expanding Tests

The tubes shall withstand expanding by a drift expander having a total included angle of between 40° and 60° (20° to 30° each side) to the following increases in external diameter without showing crack or flaw:-

Thickness of Tube                                   Increase in diameter per cent
10 S.W.G. and thinner                               12½
Thicker than 10 S.W.G. upto and including 6 S.W.G.  9½
Thicker than 6 S.W.G.                               6½

In lieu of the expending test, the flaring test carried out in accordance with any other standard code may be accepted in which case the Code adopted shall be specified.