BETAIndependent engineering reference. Source-text verification is ongoing.Verification ongoing.Verification status →
IBRsourceIndian Boiler Regulations, made clear

Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)

Regulation 49A — Tensile Test

Unofficial DPIIT web edition · not verified0 amendments found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine). This page was revised after the 2019 capture, so later amendments may be included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
  [image] [image]


Message from
Chairman of Central Boilers Board
•
About Central Boilers
Board
•
History of Indian Boiler Regulations
•
Foreword
•
Contents Chapter
Wise
•
Contents Regulation
Wise
•
List of Amendments
•
Indian Boilers
Act 1923
•
Ibr Forms
•
Home
•
Search
•
Help
•
Contact Us

[image]

[image]
Reg. 49 A
MATERIALS OF CONSTRUCTION

SEAMLESS FERRITIC AND AUSTENITIC ALLOY STEEL BOILER, SUPERHEATER AND HEAT EXCHANGER TUBES

Tensile and hardness tests

The test specimen shall comply with the requirements as given in Table 3.  The hardness test may be carried out on the wall cross section or on a flat on the outside surface of the tube sample.

TABLE 3

MECHANICAL PROPERTY REQUIREMENTS

Grade

Yield strength

Mpa (kg/mm2)

Min

Tensile Strength

Mpa (kg/mm2)

Min

% Elongation

on

GL=50mm min *

          Hardness

HRB              HB

max               max

T1

205 (21.1)

380 (38.7)

30

   80                 146

T2

205 (21.1)

415 (42.2)

30

   85                 163

T5

205 (21.1)

415 (42.2)

30

   85                  163

T9

205 (21.1)

415 (42.2)

30

   89                 179

T11

205 (21.1)

415 (42.2)

30

   85                 163

T12

220 (22.5)

415 (42.2)

30

   85                 163

T22

205 (21.1)

415 (42.2)

30

   85                 163

T91

415 (42.2)

585 (59.6)

20

   25 HRC         250  

12X1Mf

274 (28.0)

441 (45.0)

637 (65.0)

21

   85                 163

X20Cr

MoV121

490 (50.0)

690 (70.4)

840 (85.7)

17

   25HRC          250

TP 304

205 (21.1)

515 (52.5)

35

   90                 192

TP304H

205 (21.1)

515 (52.5)

35

   90                 192

TP304L

170 (17.3)

485 (49.5)

35

   90                 192

TP310S

205 (21.1)

515 (52.5)

35

   90                 192

TP316

205 (21.1)

515 (52.5)

35

   90                 192

TP316H

205 (21.1)

515 (52.5)

35

   90                 192

TP316L

170 (17.3)

485 (49.5)

35

   90                 192

TP321

205 (21.1)

515 (52.5)

35

   90                 192

TP321H

205 (21.1)

515 (52.5)

35

   90                 192

TP347

205 (21.1)

515 (52.5)

35

   90                 192

TP347H

205 (21.1)

515 (52.5)

35

   90                 192

*GL = 5.65ÖSO”.

 

[image] [image]
[image] [image] [image]
Message from Chairman of Central Boilers Board • About Central Boiler Board • History of Indian Boiler Regulations • Foreword • Contents Chapter Wise • Contents Regulation Wise • List of Amendments
• Indian Boilers Act 1923 • Ibr Forms • Home • Search • Help • Contact Us
Earlier text: the 2008 DIPP web edition

MATERIALS OF CONSTRUCTION

SEAMLESS MOLYBDENUM STEEL BOILER AND SUPERHEATER TUBES FOR DESIGN METAL TEMPERATURES NOT EXCEEDING 510 DEGREE C (950 DEGREE F).

Tensile Test

Test pieces cut from the ends of the selected tubes shall comply with the following requirements. The test may be carried out on the test pieces cut out from the tube in the longitudinal direction which shall not be further heat treated not straightened with in the gauge length. As an alternative, tubes may be tested on full cross-section.

Kind of Steel             Tensile Strength minimum             *Elongation on
                               kg./mm²          tons/sq. inch  Lo = 5do or
                                                               Lo = 5.65 (Ao)¹ᐟ²
                                                               % minimum
Molybdenum Steels                37.5               24         22

*Note

Lo = original gauge length;

do = original diameter; and

Ao = original area of cross section.