Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 49A — Tensile Test
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine). This page was revised after the 2019 capture, so later amendments may be included. Units as printed.
| [image] | [image] |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Earlier text: the 2008 DIPP web edition
MATERIALS OF CONSTRUCTION
SEAMLESS MOLYBDENUM STEEL BOILER AND SUPERHEATER TUBES FOR DESIGN METAL TEMPERATURES NOT EXCEEDING 510 DEGREE C (950 DEGREE F).
Tensile Test
Test pieces cut from the ends of the selected tubes shall comply with the following requirements. The test may be carried out on the test pieces cut out from the tube in the longitudinal direction which shall not be further heat treated not straightened with in the gauge length. As an alternative, tubes may be tested on full cross-section.
Kind of Steel Tensile Strength minimum *Elongation on
kg./mm² tons/sq. inch Lo = 5do or
Lo = 5.65 (Ao)¹ᐟ²
% minimum
Molybdenum Steels 37.5 24 22
*Note
Lo = original gauge length;
do = original diameter; and
Ao = original area of cross section.