Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 355 — Loose Flanges
Unofficial DPIIT web edition · not verified0 amendments found
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine). The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
| Reg. 355 Loose Flanges
|
Earlier text: the 2008 DIPP web edition
Loose Flanges
Loose flanges may be used where the joints are made by metal to metal faces integral with ends of the pipes. Alternatively these joints may be welded or seal welded. The loose flange shall conform to the given values.
Where the joint is formed by integral flanges, these after machining shall be not less in thickness than the designed thickness of the pipe as calculated by Equation (91).