Reg. 355

Loose Flanges

Loose flanges may be used where the joints are made by metal to metal faces integral with ends of the pipes. Alternatively these joints may be welded or seal welded. The loose flange shall conform to the given values.

Where the joint is formed by integral flanges, these after machining shall be not less in thickness than the designed thickness of the pipe as calculated by Equation (91).
Earlier text: the 2008 DIPP web edition

Loose Flanges

Loose flanges may be used where the joints are made by metal to metal faces integral with ends of the pipes. Alternatively these joints may be welded or seal welded. The loose flange shall conform to the given values.