BETAIndependent engineering reference. Source-text verification is ongoing.Verification ongoing.Verification status →
IBRsourceIndian Boiler Regulations, made clear

Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)

Regulation 354 — Screwed on Flanges

Unofficial DPIIT web edition · not verified0 amendments found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine). The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
Reg. 354

Screwed on Flanges

Where flanges are secured by screwing the screw thread on the pipes and in the flanges shall be arranged to end at a point just inside the back of boss of the flange. After the flange has been screwed on, the pipe shall be expanded into the flange by a roller expander. Such screwed and expanded flanges may be used for steam for a maximum working pressure of 31.5 kg/cm² (450 lbs./sq. in) and a maximum temperature of 399°C (750°F) and for feed for a maximum pressure of 42 kg/cm² (600 lbs./sq. in.).
Earlier text: the 2008 DIPP web edition

Screwed on Flanges

Where flanges are secured by screwing the screw thread on the pipes and in the flanges shall be arranged to end at a point just inside the back of boss of the flange. After the flange has been screwed on, the pipe shall be expanded into the flange by a roller expander. Such screwed and expanded flanges may be used for steam for a maximum working pressure of 31.5 kg/cm² (450 lbs./sq. in) and a maximum temperature of 399°C (750°F) and for feed for a maximum pressure of 42 kg/cm² (600 lbs./sq. in.).