Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 28 — Rivet Bars
Unofficial DPIIT web edition · not verified0 amendments found
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine). The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
| Reg. 28 MATERIALS OF CONSTRUCTION WROUGHT IRON STAY AND RIVET BARS |
| The tensile breaking strength shall be between 21 and 25 tons with an elongation of not less than 25 per cent measured on the standard Test Piece B (as rolled) or 30 per cent measured on the Standard Test Piece B1 (as rolled). |
Earlier text: the 2008 DIPP web edition
MATERIALS OF CONSTRUCTION
WROUGHT IRON STAY AND RIVET BARS
Rivet Bars
The tensile breaking strength shall be between 21 and 25 tons with an elongation of not less than 25 per cent measured on the standard Test Piece B (as rolled) or 30 per cent measured on the Standard Test Piece B1 (as rolled).