Reg. 25
MATERIALS OF CONSTRUCTION

STEEL PLATES, RIVETS, SECTION AND BARS IN CARBON STEEL

Facilities for inspection

The maker shall adopt a system of making the ingots, billets, slabs, plates, bars, etc. which will enable all finished material to be traced to the original charge, and the Inspector or Inspecting Officer shall be given every facility for tracing all plates and bars to their respective charges, and for witnessing the required tests. When he is satisfied with the material and with the results of the tests, he shall be furnished with two copies of the advice notes of the material for his signature.
Earlier text: the 2008 DIPP web edition

MATERIALS OF CONSTRUCTION

STEEL PLATES, RIVETS, SECTION AND BARS IN CARBON STEEL

Facilities for inspection

The maker shall adopt a system of making the ingots, billets, slabs, plates, bars, etc. which will enable all finished material to be traced to the original charge, and the Inspector or Inspecting Officer shall be given every facility for tracing all plates and bars to their respective charges, and for witnessing the required tests. When he is satisfied with the material and with the results of the tests, he shall be furnished with two copies of the advice notes of the material for his signature.

Amendments found

Machine-assisted list from the amending notifications (DPIIT copies; 1990–1998 from scanned Gazette issues on India Code); may be incomplete.

DateNotificationPartActionWhat changed (summary)Web edition
2010-10-07G.S.R. 821(E)AmendedReplaces 'Inspector or Inspecting officer' with 'Competent Person'.listed before the capture