Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 22 — Additional tests before rejection
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine). The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 22 MATERIALS OF CONSTRUCTION STEEL PLATES, RIVETS, SECTION AND BARS IN CARBON STEEL |
| Should the test pieces first selected by the Inspector or Inspecting Officer not fulfil the test requirements, two further tests of the same kind may be made, but should either of these fail, the plates or bars from which test pieces were cut shall be rejected. In all such cases further tests shall be made before any material from the same charge can be accepted. If the unsatisfactory result of a test is obviously due to technical conditions of the testing method or to a closely limited defects of a test piece, then the failure can be left out of consideration in the decision on the fulfilment of the requirement and another test piece may be substituted. If the unsatisfactory result of test is due to an unfavourable heat treatment the plate and the test strip may be heat treated again. Following this, the entire test shall be repeated. |
Earlier text: the 2008 DIPP web edition
MATERIALS OF CONSTRUCTION
STEEL PLATES, RIVETS, SECTION AND BARS IN CARBON STEEL
Additional tests before rejection
Should the test pieces first selected by the Inspector or Inspecting Officer not fulfil the test requirements, two further tests of the same kind may be made, but should either of these fail, the plates or bars from which test pieces were cut shall be rejected. In all such cases further tests shall be made before any material from the same charge can be accepted.
If the unsatisfactory result of a test is obviously due to technical conditions of the testing method or to a closely limited defects of a test piece, then the failure can be left out of consideration in the decision on the fulfilment of the requirement and another test piece may be substituted. If the unsatisfactory result of test is due to an unfavourable heat treatment the plate and the test strip may be heat treated again. Following this, the entire test shall be repeated.
Amendments found
Machine-assisted list from the amending notifications (DPIIT copies; 1990–1998 from scanned Gazette issues on India Code); may be incomplete.
| Date | Notification | Part | Action | What changed (summary) | Web edition |
|---|---|---|---|---|---|
| 2010-10-07 | G.S.R. 821(E) | Amended | Replaces 'Inspector or Inspecting officer' with 'Competent Person'. | listed before the capture |