Regulation 203 — Stresses in steel jointed stays
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 204, 205, 206. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 203, Reg. 204, Reg. 205, Reg. 206 STAYS Stresses in steel jointed stays
Reg. 204 STAYS Stay Tubes For stay tubes, whether of wrought iron or steel, seamless or electric resistance welded or lap-welded the maximum working pressure shall be calculated from the following formula :-
where
Reg. 206 STAYS Measurements of stayed areas in the end plates of Locotype and Vertical Boilers When the areas supported by stays are semi-circular as in the upper parts of the end plates and smokebox tube plates of locotype boilers, or annular as in the crown plates of vertical type boilers, the area to be supported by stays A in Eqn. 39 and 40 shall, in the first case, be the area of plate contained within the margins credited to casing or barrel sides, screw stays, fire door ring or tube stays as the case may be and in the second case be the area of the annulus between the margins credited to uptake and shell. When bolt staying is necessary the stays shall be properly distributed; the aggregate stay section shall then be used in the formula for calculating the working pressure. |
Earlier text: the 2008 DIPP web edition
STAYS
Stresses in steel jointed stays
a)The section of least strength whether of stay, rivets, shackle or pin shall be used in calculating the working pressure for the stay. For parts in tension a stress of 9,000 lbs. per square inch of net section shall be allowed, and for parts in shear stress of 8,000 lbs. per square inch of net section,
b)Parts as in double shear shall be allowed a section of 1.875 times the single section.