Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 201 — Manholes and Mudholes in Flat Plates
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulation 202. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 201, Reg. 202 FLAT PLATES Manholes and Mudholes in Flat Plates Where a flat plate is flanged to stiffen it at a manhole or sighthole, to permit same working pressure as would be allowed upon an unpierced plate, the depth of the flange measured from the other surface shall be at least equal to - (T x W)1/2 = depth of flange in inches Eqn. (38) where T = the thickness of the plate in inches, and W = the minor axis of the hole in inches. Reg. 202 STAYS Solid screwed stays For screw stays to combustion chambers and fire boxes and for longitudinal and cross stays the maximum working pressure for the stays is to be calculated from the appropriate one of the following two formulae :-
where W.P. = the working pressure in lbs. per square inch. D = the diameter of stays over threads in inches, D1 = the diameter of body of stay at its smallest part in inches N = the numbers of threads of stay per inch, A = the area in square inches supported by one stay for area to be supported by stays near tubes in firebox tube plates of locotype boilers, see Regulation 193(e). |
Earlier text: the 2008 DIPP web edition
FLAT PLATES
Manholes and Mudholes in Flat Plates
Where a flat plate is flanged to stiffen it at a manhole or sighthole, to permit same working pressure as would be allowed upon an unpierced plate, the depth of the flange measured from the other surface shall be at least equal to -
(T x W)¹ᐟ² = depth of flange in inches Eqn. (38)
where
T = the thickness of the plate in inches, and
W = the minor axis of the hole in inches.