Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 188 — Complete hemisphere without stays or other support made of one or more plates and subject to internal pressure
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine). The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 188 DISHES END PLATES Complete hemisphere without stays or other support made of one or more plates and subject to internal pressure The maximum working pressure shall be determined by the following formula : -
where W.P. is the working pressure in lbs per square inch, t is the thickness of the end plate in 32nds of an inch, S is the minimum tensile breaking strength of the end plates in tons per square inch, or whatever strength is allowed for them, J is the least percentage of strength of the riveted joints of the plates forming the hemisphere or securing it to be cylindrical shell, R is the inner radius of curvature in inches. C for single riveting is 3.3, C for double riveting is 2.9, C for treble riveting is 2.83. |
Earlier text: the 2008 DIPP web edition
DISHES END PLATES
Complete hemisphere without stays or other support made of one or more plates and subject to internal pressure
The maximum working pressure shall be determined by the following formula : -
(t - 2) x S x J
W. P. = Eqn.(23)
C x R
where
W.P. is the working pressure in lbs per square inch,
t is the thickness of the end plate in 32nds of an inch,
S is the minimum tensile breaking strength of the end plates in tons per
square inch, or whatever strength is allowed for them,
J is the least percentage of strength of the riveted joints of the plates
forming the hemisphere or securing it to be cylindrical shell,
R is the inner radius of curvature in inches.
C for single riveting is 3.3,
C for double riveting is 2.9,
C for treble riveting is 2.83.