Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 180 — Percentage of Welded and Strapped Seams
Unofficial DPIIT web edition · not verified0 amendments found
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 178, 179, 181. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
| Reg. 178, Reg. 179, Reg. 180, Reg. 181 SHELLS When Pitch exceeds maximum allowed Should the pitch of the rivets exceed the maximum pitch allowed, the permissible pitch shall be used in place of the actual pitch in determining the percentage of plate section. No greater percentage than 85 shall be allowed for any type of riveted joint. Reg. 179 SHELLS Butt Straps and spacing of rivets below requirements Should the spacing of the rows of rivets or the distance between edge of plate and rivet hole or the thickness of butt straps be less than that specified in Regulations 182 and 184 the percentage representing the strength of joint shall be modified as prescribed in those regulations. Reg. 180 SHELLS Percentage of Welded and Strapped Seams In determining the percentage of strength of a welded seam covered by a strap or straps the formulae and allowances in Regulations 177, 178 and 179 shall be applied, but 50 per cent shall be added to the rivet percentage for the weld. Reg. 181 SHELLS Percentage to be allowed for Solid Rolled Shells When small shells are rolled from the solid, J, in equation (1) shall be taken as 100 per cent. |
Earlier text: the 2008 DIPP web edition
SHELLS
Percentage of Welded and Strapped Seams
In determining the percentage of strength of a welded seam covered by a strap or straps the formulae and allowances in Regulations 177, 178 and 179 shall be applied, but 50 per cent shall be added to the rivet percentage for the weld.
Possible IBR 2026 successors (heading match, unverified): Reg. 433