Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 172B — Tolerances on shanks
Unofficial DPIIT web edition · not verified0 amendments found
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 172A, 172C. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
| Reg. 172-A RIVETING Rivet Heads The rivet heads shall be of any one of the form(shown in sketch (1) Appendix H-4) given below: 1. Snap head. 2. Ellipsoidal head. 3. Pan head. 4. Conical head. 5. Round countersunk head. 6. Pan head with tapered neck. 7. Steeple head. 8. Countersunk head. The dimensions of these rivet heads shall conform to the proportions indicated in the sketch. The Chief Inspector may, at his discretion, accept any slight variation in the proportion of these dimensions and forms. Reg. 172-B RIVETING Tolerances on shanks The tolerances on the diameters of the shanks measured at position XX, YY, ZZ shown in sketch 2,Appendix H-4 shall be within the limits given in table below:- Diameter of Shanks
Reg. 172-C RIVETING Rivet Holes
| ||||||||||||||||||||||||||||||||||||
Earlier text: the 2008 DIPP web edition
RIVETING
GENERAL
Tolerances on shanks
The tolerances on the diameters of the shanks measured at position XX, YY, ZZ shown in sketch 2 shall be within the limits given in table below:-
Diameter of Shanks
Reference Distance from For rivets 5D and below in length For rivets over 5D in
position as rivet head or length
shown in end
Sketch-2
Appendix H-4
Max. Min. Max Min.
XX D/8 plus 3/8” D+1/64” D D + 1/64” D
for D=1” for D=1”
and under and under
YY D/2 from end D D-1/64” D D-
1/64”
ZZ D/2 from end - - - D-
1/64”