BETAIndependent engineering reference. Source-text verification is ongoing.Verification ongoing.Verification status →
IBRsourceIndian Boiler Regulations, made clear

Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)

Regulation 171 — Rivets securing compensating rings and Stand Pipes

Unofficial DPIIT web edition · not verified0 amendments found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine). The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
Reg. 171
MANHOLES, MUDHOLES, ETC.
Rivets securing compensating rings and Stand Pipes

a) For manholes or frames - The total effective shear strength of the rivets on each side of the longitudinal centre line shall be not less than the tensile strength of that portion of the shell plate, as found by Regulation 170, which is removed and the rivets securing any compensating ring or frame shall be so arranged that the joint efficiency calculated on any line parallel to the axis of the boiler through any part of such ring or frame shall not be less than the efficiency of the longitudinal seam of the boiler.
b) For stand pipes - Where the hole in the shell to accommodate a stand-pipe does not exceed 8 inches diameter the total effective shear strength of the rivets on each side of the longitudinal centre line shall not be less than 75 per cent of the tensile strength of the portion of the plate, as found by Regulation 170, which has been removed.

The strength of rivets in double shear shall be taken as 1.875 times the strength of rivets in single shear.
Earlier text: the 2008 DIPP web edition

MANHOLES, MUDHOLES, ETC.

GENERAL

Rivets securing compensating rings and Stand Pipes

a)For manholes or frames - The total effective shear strength of the rivets on each side of the longitudinal centre line shall be not less than the tensile strength of that portion of the shell plate, as found by Regulation 170, which is removed and the rivets securing any compensating ring or frame shall be so arranged that the joint efficiency calculated on any line parallel to the axis of the boiler through any part of such ring or frame shall not be less than the efficiency of the longitudinal seam of the boiler.

b)For stand pipes - Where the hole in the shell to accommodate a stand-pipe does not exceed 8 inches diameter the total effective shear strength of the rivets on each side of the longitudinal centre line shall not be less than 75 per cent of the tensile strength of the portion of the plate, as found by Regulation 170, which has been removed.

The strength of rivets in double shear shall be taken as 1.875 times the strength of rivets in single shear.