Regulation 165 — Compensating Rings and Frames for Openings in Shells

Unofficial DPIIT web edition · not verified0 amendments found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine). The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
Reg. 165
MANHOLES, MUDHOLES, ETC.
Compensating Rings and Frames for Openings in Shells

a) Compensating rings and frames for openings in shells shall be of wrought or cast steel. The compensation provided shall preferably be flanged frames, which shall be fitted in all cases where the shell plate exceeds 9/16 inch thick. Flanged frames shall be weldless and shall be flanged or pressed to provide a flat jointing surface for the cover.
b) All compensating rings and frames shall be formed to bed closely to the surfaces to be connected. Where attached to cylindrical shells and are 12 inches x 9 inches or larger they shall be atleast double riveted. All caulking edges shall be machined or machine gas cut.
c) The flat jointing surfaces of all flanged or pressed frames and all doors or covers shall be machined.
Earlier text: the 2008 DIPP web edition

MANHOLES, MUDHOLES, ETC.

GENERAL

Compensating Rings and Frames for Openings in Shells

a)Compensating rings and frames for openings in shells shall be of wrought or cast steel. The compensation provided shall preferably be flanged frames, which shall be fitted in all cases where the shell plate exceeds 9/16 inch thick. Flanged frames shall be weldless and shall be flanged or pressed to provide a flat jointing surface for the cover.

b)All compensating rings and frames shall be formed to bed closely to the surfaces to be connected. Where attached to cylindrical shells and are 12 inches x 9 inches or larger they shall be atleast double riveted. All caulking edges shall be machined or machine gas cut.

c)The flat jointing surfaces of all flanged or pressed frames and all doors or covers shall be machined.