Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 150 — Load on Stay Tubes
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulation 149. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 149, Reg. 150 STAY TUBES Thickened ends of Stay Tubes If stay tubes are required to have their thickness increased at the screwed ends so that the thickness at the bottom of the threads is approximately the same as in the body of the tube the thickening shall be attained by upsetting and not by welding process, and the tubes shall be annealed after the upsetting. Reg. 150 STAY TUBES Load on Stay Tubes Stay tubes shall be designed to carry the whole load due to pressure on the area to be supported. In each case the area to be calculated is as follows:-
|
Earlier text: the 2008 DIPP web edition
STAY TUBES
GENERAL
Load on Stay Tubes
Stay tubes shall be designed to carry the whole load due to pressure on the area to be supported. In each case the area to be calculated is as follows:-
a)For a stay tube within the tube nest the net area to be supported shall be product of the horizontal and vertical pitches of the stay tube less the area of the tube holes embraced. Where the pitch of the stay tube is irregular the area shall be taken as the square of the mean pitch of the stay tubes (i.e., one quarter the sum of four sides of any quadrilateral bounded by four adjacent stay tubes) less the area of the tube holes embraced.
b)For a stay tube in the boundary row the net area to be supported shall be the area enclosed by lines passing midway between it and the adjacent points of support less the area of any tubes embraced. The adjacent points of support may be other stay tubes, or the commencement of curvature of flanging of centre line of the circle of rivets securing the end plate to the shell angle.