Regulation 143 — Load on Gusset Stay

Unofficial DPIIT web edition · not verified0 amendments found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 142, 144. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
Reg. 142, Reg. 143, Reg. 144
GIRDER STAYS
Gussets Angles

The gusset angles connecting the stays to the shell and end plates shall be at least 7/8ths of the thickness of the shell plate, but shall be not less than ½ inch in thickness.


Reg. 143
GIRDER STAYS
Load on Gusset Stay

Each gusset stay supporting the end plate of a boiler shall be designed to carry the whole load due to pressure on the area supported by it.


Reg. 144
GIRDER STAYS
Gusset Riveting

a) Rivets securing gusset stays shall not be less in diameter than the thickness of the cylindrical shell plate and the riveting shall be arranged so that the strength of the shell plate where drilled for the gusset rivets shall not be less than the strength of the longitudinal seams.
b) Not less than three rivets shall be used to connect any gusset plate to any angle or any angle to the end plate or to the shell plate.
Earlier text: the 2008 DIPP web edition

GIRDER STAYS

GENERAL

Load on Gusset Stay

Each gusset stay supporting the end plate of a boiler shall be designed to carry the whole load due to pressure on the area supported by it.