BETAIndependent engineering reference. Source-text verification is ongoing.Verification ongoing.Verification status →
IBRsourceIndian Boiler Regulations, made clear

Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)

Regulation 137 — Stay Nuts

Unofficial DPIIT web edition · not verified0 amendments found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 136, 138. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
Reg. 136, Reg. 137, Reg. 138
SCREWED STAYS
Axial drilling

All screwed stays less than 14 inches long should preferably be drilled with a tell-tale hole 3/16 inch diameter to a depth of ½ inch beyond the inner face of the plate. Stays which are obscure on one side should preferably be made from hollow staybar.


Reg. 137
SCREWED STAYS
Stay Nuts

a) Nuts to screw stays in combustion chambers and fireboxes shall not be less than ¾ inch thick for stays upto 1½ inches diameter over threads, 7/8 inch thick for 1 5/8 inches and 1¾ inches stays, 1 inch thick for 1thick 1 7/8 and 2 inches stays, and 1 1/8 inches thick for stays over 2 inches in diameter.
b) The nuts shall be made of solid mild steel or of iron which shall be without weld if exposed to flame.


Reg. 138
SCREWED STAYS
Spacing of End Stays – Allowance for curves, etc.

For the topes of fireboxes and combustion chambers the distance between the rows of stays nearest to the tube plate or firehole plate or back plate as the case may be, and the commencement of curvature of these plates at their flanges shall not be greater than the horizontal pitch of the stays.
Earlier text: the 2008 DIPP web edition

SCREWED STAYS

GENERAL

Stay Nuts

a)Nuts to screw stays in combustion chambers and fireboxes shall not be less than ¾ inch thick for stays upto 1½ inches diameter over threads, 7/8 inch thick for 1 5/8 inches and 1¾ inches stays, 1 inch thick for 1thick 1 7/8 and 2 inches stays, and 1 1/8 inches thick for stays over 2 inches in diameter.

b)The nuts shall be made of solid mild steel or of iron which shall be without weld if exposed to flame.