IBR 1950 — Chapter IX-A

OCR of DPIIT's scanned historical print edition of the Indian Boiler Regulations, 1950 (imperial units; consolidation date unknown). This is NOT the text as in force on 30 September 2026. OCR errors are expected; check the scanned page.

Scan image 1 open scan

241

CHAPTER IX-A
SAFETY OF PERSONS INSIDE BOILERS

396. Safety of persons working inside boilers.-(a) No person shall be compelled or allowed, by
the owner or person in charge, to go inside a steam boiler for any
purpose whatsoever unless the boiler is effectively disconnected in
the manner hereinafter prescribed from any steam or hot water
communica- tion with any other boiler.

(b) Effective disconnection shall be made either by the removal of the boiler stop valve or of a
length of piping from all steam and hot water connec- tions with any
other boiler, vessel or pipe containing steam or hot water or by the insertion
of substantial blank flanges between the boiler stop valves and piping. The
shutting of a stop valve, stop cock or automatic isolating valve alone
shall not be deemed to constitute compliance with this Regulation. In
the case of welded pipe work, however, if a vent pipe of not less than 2" inter-
nal diameter (bore) is fitted between the main stop valve and the
intermediate stop valve on the steam main and between the feed check
valve and interme- diate check valve on the feed line, this Regulation shall
be considered to have been complied with, provided such vent pipes are
fitted with bolted-on blank flanges and the flanges are removed so as to
effectively discharge any leakage steam or water to the atmosphere when
the valves on either side of its have been closed

(c) The owner of a boiler to which this Regulation is applicable shall obtain the approval of the
Chief Inspector in writing to the method of dis- connection which he
proposes to use and shall be responsible for ensuring that the method so
approved is followed in practice.

(d)